| Model Type |
SMART KING RM |
|
| Model Name |
SMK-2000A-RM |
|
 |
AC INPUT
|
|
| AC Input Capacity on Battery |
2000VA |
|
| AC Input Voltage |
(+/-) 25% at line input |
|
| AC Input Frequency |
50 or 60 Hz+/-5Hz (auto sensing) |
|
| AC Input Phase |
Single |
|
 |
AC OUTPUT
|
|
| AC Output Voltage |
Pure sine wave at +/-5% of nominal, -10% of nominal after low battery warning |
|
| AC Output Frequency |
50 or 60 Hz +/- 0.5% |
|
| AC Output Voltage Regulation |
AVR automatically increase output voltage 15% above input voltage if -9% to -25% of nominal. AVR decrease output voltage 15% below input voltage if +9% to +25% of nominal |
|
 |
PROTECTION
|
|
| Protection Spike |
320 Joules, 2ms |
|
| Protection EMI/RFI |
10dB at 0.15 MHz, 50 dB at 30 MHz |
|
| Protection Overload |
UPS automatic shutdown if overload exceeds 110% nominal at 20 sec and 125% at 5 sec |
|
| Protection Unit |
Fuse for 110V models (600VA~2500VA) and 220V models (under 1250VA), breaker for 110V model (3000VA) and 220V models (above 1500VA) |
|
| Protection Transfer Time |
2/4 milliseconds (typical), including detection time |
|
| Protection Short Protection |
UPS output cut off immediately or input fuse( or breaker) protection |
|
 |
BATTERY
|
|
| Battery Type |
Hot swappable, sealed, maintenance-free lead acid, with 3 - 6 year lifetime |
|
| Battery Typical |
4 hours (to 90% of full capacity) |
|
| Battery Protection |
Automatic self-test & discharge protection, replace battery indicator |
|
| Battery Run Time |
120 minutes |
|
 |
PHYSICAL
|
|
| Physical Weight lbs Tower |
N/A |
|
| Physical Weight kgs RM |
28.4 |
|
| Physical Weight lbs RM |
(62.5lb) |
|
| Physical Dimension mm Tower |
N/A |
|
| Physical Dimension inch Tower |
N/A |
|
| Physical Dimension mm RM |
483x381x130 |
|
| Physical Dimension inch RM |
(19.0 |
|
 |
INDICATOR
|
|
| LCD Indicators Status |
Indicate line, bypass, inv, backup, fault, bat capacity, load capacity, I/P frequency, O/P voltage, O/P frequency, inside temperature, fault status, load |
|
| LED |
LED |
|
 |
ALARM
|
|
| Alarm Battery Backup |
Slow beeping sound (about 0.25 Hz) |
|
| Alarm Battery Low |
Rapid beeping sound (about 1.00Hz) |
|
| Alarm Overload |
Continue beeping sound |
|
 |
INTERFACE
|
|
| Interface Dry Contact |
Sends AC fail and battery low signals, and receives shutdown signal from computer |
|
| Interface RS-232 |
Detect battery low, Schedule UPS on/off, AC input/output power status display |
|
| Interface Option |
Novell, SNMP, Windows NT, Window 95/98/2000/ME/XP |
|
 |
ENVIRONMENT
|
|
| Environment Ambient |
3,500 meters max. elevation, 0-95% humidity non-condensing, 0-48 deg c |
|
| Environment Audible |
<40dBA (1 meter from surface) |
|
| Environment Storage Condition |
15,000 meters max. elevation |
|
| ShowOrder |
51 |
|
 |